The vast series of electronic equipments Cullwater are been created to front the new exigencies of the swimming pools and the treatment of civil and industrial waters. The electronic instruments are extremely easy to install and to manage, permitting the control of the flow rate, the electric conductivity, the temperature, the free chlorine, the Redox potential and the pH.
|
|
|
|
|
Measuring and regulation DIN bar instruments
|
PH-D: instrument for measuring and regulation of pH
MV-D: instrument for measuring and regulation of the Redox potential
CL-D: instrument for measuring and regulation of the free Chlorine
CLO-D: instrument for measuring and regulation of the Chlorine Dioxide
MS-D: instrument for measuring and regulation of the Conductivity
O2-D: instrument for measuring and regulation of the Dissolved Oxygen
O3-D: instrument for measuring and regulation of the Ozone
°C-D: instrument for measuring and regulation of the Temperature |
|
Technical features of the DIN bar instruments:
Power supply:
230 V - 50/60 Hz, Degree of protection
IP 20, Regulation 2 manual adjustable set points on-off
with the timer, Exit signal 0/4...20
mA, Dimensions of the size L - H - P in mm. 105 - 90 - 55.
|
|
|
Measuring and regulation wall-installation instruments
|
|
PH-S: instrument for measuring and regulation of pH
MV-S: instrument for measuring and regulation of Redox potential
CL-S: instrument for measuring and regulation of the free Chlorine Dioxide
MS-S: instrument for measuring and regulation of the Conductivity
O2-S: instrument for measuring and regulation of Dissolved Oxygen
PHMV-S: instrument for measuring and regulation of pH and Redox
PHCL-S: instrument for measuring and regulation of pH and free Chlorine
PHMS-S: instrument for measuring and regulation of pH and Conductivity
PHMVCL°C-S: instrument for measuring and regulation of pH, Redox, free Chlorine and Temperature
|
Technical features of wall-installation instruments: Power supply
22-265 V - 50/60 Hz, Degree of protection
IP 65, Regulation 2 manual adjustable set points on-off with the timer and indication of the electrode's quality,
Exit signal 0/4...20 mA,
Dimension of the size L - H - P in mm. 145 - 145- 90.
|
|
|
Electromagnetic metering pumps with an integrated control instrument
|
PPPH:
digital metering pump with integrated pH control instrument
PPRX: digital metering pump with integrated Redox control instrument
PPCL: digital metering pump with integrated free Chlorine control instrument
|
 |
|
|
Technical features of electromagnetic metering pumps:
Power supply 230 V - 50/60 Hz, Degree of protection IP 65,
Capacity 2-70 lt./h. regulation 0-100%,
Pressure 0-20 Bar, Temperature of working -10...40°
C, Dimensions of the size (compresa base in PP) L - H - P in mm.
110 - 235 - 150. Entrance of the level probe . Installation kit included. Pump body and connections in PP, o-rings in EPDM, Diaphragm in PTFE, Pyrex balls. Optional Execution: Pump body and PVDF connections , ceramic balls.
|
|
|
|
|
Regulation and measuring system |
|
Assembled panels for the measure and the control of: PH - Redox and Free Chlorine
Electric conductivity - Dissolved Oxygen - Flow rate - Temperature - Turbidity
|
|
|
|
Version with metering pumps with a control instrument integrated |
|
|
Panel for the measuring and regulation of the pH value and of the Redox potential (ORP)
- Fields of regulation from 0-14 pH and 0-900 mV
- 2 metering pumps model PPPH and PPRX with integrated instrument and level probes
- pH electrode
- RX electrode
- Automatic calibration with quality control of the electrodes
- Mechanical filter at the water entrance
- Electrode holder
- Panel measures in mm. 500 x 450
|
|
|
|
|
|
|
|
|
|
| Version with wall-instruments |
PHMV - P
Panel for the measure and the regulation of the pH value and of Redox potential (ORP)
|
-
Control PHMV-S model instrument: fields of regulation from 0-14 PH (resolution 0.01 PH) and 0-1000 mV (resolution 1 mV) 2 on-off or proportional set points, exit 0/4...20 mA. Compensation of the temperature in pH thanks to the E-TL model drill (optional). Instrument in box IP65.
2 metering pumps with constant dosage PCB model. Possibility of proportional dosage into intervals of codifying measure with metering pumps PPMA model. Capacity of the dosage
Lt/h Pressure : 0-20 bar
-
pH electrode
-
RX electrode
-
Mechanical filter at the water entrance
-
Electrode holder complete of flow sensor
-
Panel measure in mm L X H 800 X 600
-
Optional:
Additional metering pumps fixed on the panel for the dosage of flocculating and algaecide.
|
|
|
|
|
|
|
|
PHCL
- P
Panel for the measure and the regulation of the pH value and free Chloride
|
-
PHCL-S model control instrument: fields of regulation from 0-14 PH (resolution 0.01 PH) and 0-10 mg/l Cl2 (resolution 0.01 mg/l Cl2) 2 on-off or proportional set points, exit 0/4 20 mA. Compensation of the temperature in pH thanks to the E-TL model drill (optional). Instrument in box IP65.
-
2 PCB model metering pumps with constant dosage. Possibility of proportional PPMA model dosage into intervals of codifying measure with metering pumps. Capacity of the dosage 2-70 Lt/h Pressure : 0-20 bar
-
pH electrode
-
Ammeter cell of free chlorine (organic and inorganic)
-
Mechanical filter at the water entrance
-
Electrode holder complete of flow sensor
-
Panel measure in mm L X H 800 X 600
-
Optional: Additional metering pumps fixed on the panel for the dosage of flocculating and algaecide.
|
|
|
|
|
|
|
|
Versions with DIN bar instruments |
|
|
|
|
|
PHMV
- D
Panel for the measure and the regulation of the pH value and of Redox potential (ORP)
|
| |
|
 |
- Control instruments PH-D and MV-D with DIN bar model: fields of regulation from 0-14 PH (resolution 0.01 PH) and 0-1000 mV (resolution 0.01 mV) 2 on-off or proportional set points, exit 0/4...20 mA. Automatic compensation of the temperature in pH thanks to the drill E-TL model (optional). Instrument in electrical box IP65 with general switch and timer for delayed starting.
|
-
2 metering pumps with constant dosage PCB model. Possibility of proportional dosage into gaps of codifying measure with metering pumps PPMA model. Capacity of the dosage 2-70 Lt/h Pressure : 0-20 bar
-
pH electrode
-
RX electrode
-
Electrode holder complete of flow sensor
-
Panel measure in mm L X H 800 X 600
-
Misure pannello in mm. L x H: 800 x 600
-
Optional:
Additional metering pumps fixed on the panel for the dosage of flocculating and algaecide.
|
|
|
PHCL
- D
Panel for the measure and the regulation of the pH value and of free Chlorine
|
 |
-
Control instrument PH-D and MV-D with DIN bar model: fields of regulation from 0-14 PH (resolution 0.01 PH) and 0-10 mg/l Cl2 (resolution 0.01 mg/l Cl2) 2 on-off or proportional set points, exit 0/4...20 mA. Automatic compensation of the temperature in pH thanks to the drill E-TL model (optional). Instrument in electrical box IP65 with general switch and timer for delayed starting.
-
2 metering pumps with constant dosage PCB model. Possibility of proportional dosage into gaps of codifying measure with metering pumps PPMA model. Capacity of the dosage 2-70
Lt/h Pressure : 0-20 bar
- pH electrode
-
Ammeter Cell of free chlorine (organic and inorganic)
-
Mechanical filter at the water entrance
-
Electrode holder complete of flow sensor
-
Panel measure in mm L X H 800 X 600
-
Optional:
Additional metering pumps fixed on the panel for the dosage of flocculating and algaecide.
|
|
|
| |
PHMVCL - D
Panel for the measure and the regulation of the pH value, Redox (ORP) potential and of free Chlorine |
| 
|
-
Control instruments PH-D and MV-D and CL-D with DIN bar model: fields of regulation from 0-14 PH (resolution 0.01 PH) 0-1000 mV (reduction of 1 mV) and 0-10 mg/l Cl2 (resolution 0.01 mg/l Cl2) 2 on-off or proportional set points, exit 0/4...20 mA. Automatic compensation of the temperature in pH thanks to the drill E-TL model (optional). Instrument in electrical box IP65 with general switch and timer for delayed starting.
-
2 metering pumps with constant dosage PCB model. Possibility of proportional dosage into gaps of codifying measure with metering pumps PPMA model. Capacity of the dosage 2-70 Lt/h Pressure : 0-20 bar
- pH electrode
-
Rx electrode
-
Ammeter Cell of free chlorine (organic and inorganic)
-
Mechanical filter at the water entrance
-
Electrode holder complete of flow sensor
-
Panel measure in mm L X H 800 X 800
-
Optional:
dditional metering pumps fixed on the panel for the dosage of flocculating and algaecide.
|
|
|
|
|
|
|
Accessories |
|
|
|
|
|
 |
|
Electrodes for pH and Redox potential |
Amperometric cells for Free Chlorine, Chlorine Dioxide, Dissolved Oxygen, Ozone |
Electrodes holder |
|

Threaded and flanged
pulse-sender water meters
of 1/2" to 8"
|

Temperature probes

Conductivity cells
|
|

Electric mixers from 70 to 400 RPM
for dosage stations |

Storage tanks
from 60 to 1070 liters |
|