NITRATES: CAUSES AND SOLUTION OF A PROBLEM

The environmental contamination caused by nitrates is increasing in these last few years becoming a huge and relevant problem caused by the progressive and uncontrolled increase of their presence in the soil and in the deep and superficial waters. The reason of the worrying phenomena must be searched in many directions but principally in the always most frequent use of nitrogenous fertilizations in the agriculture, it the increase of the volume of the human and animal wastes and in the industrialization's process that brings about industrial wastes with high concentration of nitrogenous components which, percolating the ground, usually contaminate also the deepest ground water tables. In the last few years many scientists have put their attention on many important researches about the presence of nitrates in the water, and they now consider these substances very dangerous for the health and essentially for their effect on the methemoglobins and on the cancers.
The excessive presence of the nitrates makes a corrosive action towards zinc and tin, creating considerable inconveniences in some technological activities. The experts have also observed that when a considerable quantity of nitrates accumulates into an electroplated tank of water and you make it pass into electroplated tubes you could have a huge development of nitrites (NO2¯) for the reduction of the nitrates and this process is often wrongly attached to the pollution. The nitrates, in according to the regulations in force, are allowed in the drinkable water til to 50 mg/l NO3¯, instead in some technological uses their concentration could be considerably lower.

The double body Cullwater denitrificators are completely automatic equipments that are used for the selective removing of nitrates and sulphates or of nitrates only. This transformation is due to our particular and specific anionic resin in form as Cl¯ with ionic change, highly selected in the granulometry for a long duration and a minim consumption of regeneration (sodium chloride), necessary for the reactivation, called "A200E" for the change of nitrates and sulphates and "A520E" for the change of sulphates only.

The double body Cullwater denitrificators are built in 34 completely automatic models with connections of 3/4" till 3" with time command or volume command.

Time command: the time command makes the regeneration of the denitrificator start in precise hours and on the grounds of supposed water's consumptions. If the consumptions are variable and unpredictable the regeneration can be effected in advance (waste of regeneration) or in late (leakage of nitrates and sulphates in service).

Volumetric command: The volumetric command makes the regeneration of the denitrificator start when the resins exhaust their capacity of change with evident conservation of regenerator.

Model

Cyclic capacity and salt consumption in Kg for regeneration

Resin LT

Middle capacity in service

Diameter of connections in and out

Dimension on the floor (mm)

Capacity tank of salt Kg

Weight at the spedition in kg

 

NO3-

Kg

 

 

 

L

P

H

 

 

Automatic denitrificators S 541 double body

AeS/N 724 10A

200

2

10

5

3/4"

660

470

800

100

35

AeS/N 735 15A

300

3

15

7,5

3/4"

660

470

1100

100

40

AeS/N 835 20A

400

4

20

10

3/4"

680

470

1100

100

45

AeS/N 844 25A

500

5

25

12,5

3/4"

710

470

1360

100

50

AeS/N 1035 30A

600

6

30

15

3/4"

730

470

1100

100

55

Automatic denitrificators double body S 3000

AS/N 724 10A

200

2

10

5

1"

660

470

800

100

35

AS/N 735 15A

300

3

15

7,5

1"

660

470

1100

100

40

AS/N 835 20A

400

4

20

10

1"

680

470

1100

100

45

AS/N 844 25A

500

5

25

12,5

1"

710

470

1360

100

50

AS/N 1035 30A

600

6

30

15

1"

730

470

1100

100

55

AS/N 1040 35A

700

7

35

17,5

1"

730

470

1230

100

60

AS/N 1048 40A

800

8

40

20

1"

730

470

1430

100

65

AS/N 1054 45A

900

9

45

22,5

1"

790

530

1650

150

70

AS/N 1062 50A

1000

10

50

25

1"

850

530

1820

150

75

AS/N 1450 60A

1200

12

60

30

1"

850

530

1550

150

85

AS/N 1457 75A

1500

15

75

37,5

1"

870

530

1610

150

100

AS/N 1465 100A

2000

20

100

50

1"

890

530

1960

200

140

AS/N 1665 125A

2500

25

125

62,5

1"

940

530

1960

200

175

AS/N 2062 150A

3000

30

150

75

1"

1110

530

1850

300

210

Double body industrial Automatic denitrificators 2850

AS/N 2244 175A

3500

35

175

87,5

1.1/2"

1160

600

1450

300

240

AS/N 2254 200A

4000

40

200

100

1.1/2"

1160

600

1700

300

260

AS/N 2260 250A

5000

50

250

125

1.1/2"

1160

600

1850

300

330

AS/N 2460 300A

6000

60

300

150

1.1/2"

1320

700

1850

400

390

AS/N 2471 350A

7000

70

350

150 - 175

1.1/2" - 2"

1420

800

2140

400

450

AS/N 2471 400A

8000

80

400

150 - 200

1.1/2" - 2"

1420

800

2140

400

520

AS/N 3072 450A

9000

90

450

150 - 225

1.1/2" - 2"

1590

800

2250

500

600

AS/N 3072 500A

10000

100

500

150 - 250

1.1/2" - 2"

1790

1000

2250

500

650

AS/N 3072 550A

11000

110

550

150 - 275

1.1/2" - 2"

1790

1000

2250

800

700

AS/N 3072 600A

12000

120

600

150 - 300

1.1/2" - 2"

1790

1000

2250

800

750

AS/N 3672 750A

15000

150

750

150 - 375

1.1/2" - 2"

2300

1350

2250

1000

950

AS/N 3672 800A

16000

160

800

150 - 400

1.1/2" - 2"

2300

1350

2250

1000

1000

AS/N 4272 1000A

20000

200

1000

150 - 500

1.1/2" - 2"

2400

1350

2250

1000

1250

AS/N 4872 1250A

25000

250

1250

150 - 500 - 625

1.1/2" - 2" - 3"

2250

1350

2250

1000

1550

AS/N 4872 1500A

30000

300

1500

150 - 500 - 750

1.1/2" - 2" - 3"

2550

1350

2250

1000

1800

 

OPTIONAL

Automatic by-pass for misheling

2 flowmeters with valves of regulation of treated and not treated water

Head with connection high flow S 2900 from mod. 2471 - 2" head with connection S 3900 to model 4872 - 3"

Volumetric unit control – V connection from 1" - 1.1/2" - 2" - 3"

DATAS OF WORKING: PRESSURE min. 2 Bar - max. 7 Bar
TEMPERATURE min. °C 5 - max. °C 50 - ELECTRIC POWER: 220 / 24 Volt